Power supply unit for computers (power supply unit for computers)
Product: Power supply unit for computers (power supply unit for computers)
Product Category: Computing
Model / Type: CM-600B
Date: 2026-10-29
Hazard: ㅇ (Critical defect) 1. Inadequate clearance and creepage distance. – Insufficient insulation distance between primary (L) and earth. – Measured clearance distance: 1.90 mm (Standard limit: 2.0 mm or more). – Measured creepage distance: 1.90 mm (Standard limit: 2.5 mm or more). ㅇ If the insulation distance is insufficient, there is a risk of electric shock when a person touches live parts.
Injuries: No injury has been reported
Measures: ㅇ Consumers who have it must stop using the product immediately. ㅇ Contact and visit the place of purchase for exchange, refund or repair, etc.
Country of Origin: China (People's Republic of)
Recalling Country: Korea (Republic of)
Source: OECD GlobalRecalls portal